11/12 150139 Rev. D
1
ICE CREAM TOPPING CABINET
MODELS ZR152, ZF152 and ZF071
Installation, Operation and
Maintenance Instructions
INSPECTION
When the equipment is received, all items should be checked against the bill of lading to
insure all crates and cartons have been received. All units should be inspected for concealed
damage by uncrating the unit immediately. If any damage is found, it should be reported to
the carrier at once, and a claim should be filed with the carrier. The equipment has been
inspected and tested in the Nor-Lake manufacturing facility and has been crated in
accordance with transportation rules and guidelines. The manufacturer is not responsible for
freight loss or damage.
INSTALLATION
CASTERS
After the packaging and shipping base have been removed, locate the casters found inside
the cabinet. Attach the casters to the bottom of the cabinet using the bolts found installed in
the base (four bolts /caster). The casters with the brakes should be installed in the front of
the cabinet. Do not operate the unit without casters or legs installed.
CLEANING
The exterior of the cabinet and doors may have been protected with a plastic covering. Peel
this protective covering before installation. After removing the covering, clean the interior and
exterior surfaces of the unit with soap and water and rinse with clean water. Dry with a soft
cloth. Do not use chlorinated cleaners on the cabinet as they can cause corrosion. Do not
use abrasive cleaners or pads as they can scratch the surfaces.
DOOR ALIGNMENT
If the doors have come out of alignment during transit, they can be adjusted. This is
accomplished by losing the screws on the door hinges, adjust the door so it is aligned
properly and tighten the hinge screws.
SHELVES
The shelves and shelf clips are packaged inside the cabinet. Install the shelf clips on the
pilasters inside the unit and set the shelves on the shelf clips. The shelves are adjustable in
½” increments.
LOCATION
The refrigeration system located in the back of the unit requires space for proper operation.
In order to assure proper airflow, allow a minimum of four (4) inches on ZR cabinets and six
(6) inches on ZF cabinets of clear space on the sides and back of the cabinet.
Do not locate the unit next to heat generating equipment or in direct sunlight. Improper
installation will void the warranty.
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - ICE CREAM TOPPING CABINET

11/12 150139 Rev. D 1 ICE CREAM TOPPING CABINET MODELS ZR152, ZF152 and ZF071 Installation, Operation and Maintenance Instructions INSPECTION Wh

Pagina 2 - MAINTENANCE

11/12 150139 Rev. D 2Confirm that the proposed electrical outlet has the correct voltage, frequency and current carrying capacity for the requiremen

Pagina 3 - SERVICE

11/12 150139 Rev. D 3CONDENSER COIL Prior to cleaning the condenser coil, disconnect the unit from power. Periodic cleaning of the condenser coil w

Pagina 4 - 11/12 150139 Rev. D

11/12 150139 Rev. D 4MAINTENANCE SERVICE AND ANALYSIS GUIDE REFRIGERATION SYSTEMS - ALL MODELS MALFUNCTION POSSIBLE CAUSE SOLUTION Compressor w

Pagina 5 - INSTALLATION

11/12 150139 Rev. D 5ARMOIRES À GARNITURE DE CRÈME GLACÉE MODÈLES ZR152, ZF152 et ZF071 Instructions D'Installa

Pagina 6 - ENTRETIEN

11/12 150139 Rev. D 6EMPLACEMENT Le système de refroidissement situé à l'arrière de l'appareil nécessite un espace adéquat afin de pouvoi

Pagina 7

11/12 150139 Rev. D 7NETTOYAGE Dès la première installation, les surfaces intérieures de l’armoire et le rail doivent être essuyés périodiquement a

Pagina 8 - 11/12 150139 Rev. D

11/12 150139 Rev. D 8GUIDE D’ENTRETIEN ET D’ANALYSE SYSTÈMES FRIGORIFIQUES – TOUS MODÈLES MALFUNCTION CAUSE POSSIBLE DE LA DÉFECTUOSITÉ SOLUT